BCJCV - HENCO 1000 DETERGENT-DEGREASER

  • MSDS: BCJCV
  • Manufacturer: H A HENDERSON COMPANY
  • Product Name: HENCO 1000 DETERGENT-DEGREASER
  • National Stock Number: 6850-00N002091
Product Identification

Product ID:HENCO 1000 DETERGENT-DEGREASER
MSDS Date:01/01/1985
FSC:6850
NIIN:00N002091
MSDS Number: BCJCV

Responsible Party
H.A. HENDERSON COMPANY
5039 W JEFFERSON BLVD
LOS ANGELES, CA 90016-3940
US

Cage: HO055

Contractor
HENDERSON H A CO
LOS ANGELES, CA 90016-3940 US

Cage: 25056

Ingredients

SOLVENTS

Fraction By Weight: 48%

Hazards

Effects of Overexposure:EYE: IRRIT. SKIN: DRYING. INHAL: HEADACHE,
DIZZINESS & NAUSEA

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR & CALL MD. APPLY ARTIFICIAL
RESPIRATION IF NECESSARY. EYES: FLUSH W/ WATER FOR 15 MIN.

Fire Fighting

Flash Point:138F;59C COC
Lower Limits:1
Upper Limits:85
Extinguishing Media:CO*2,OR DRY CHEM FOR SMALL FIRES
Fire Fighting Procedures:STANDARD CHEMICAL FIRE PROCEDURES FOR LARGE
FIRES.
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION MAY YIELD CARBON
MONOXIDE,ALDEHYDES & PEROXIDES.

Accidental Release

Spill Release Procedures:FLUSH W/ WATER INTO RETAINING AREA OR
CONTAINER; AVOID EXPOSURE TO SPARKS, FIRE OR METAL SURFACES THAT
MAY BE HOT.

Handling

Handling and Storage Precautions:STORE IN COOL DRY PLACE. AVOID SPARKS
& OPEN FLAMES. USE W/ ADEQUATE VENTILATION.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPRVD AIR-SUPPLIED MASK FOR HI-CONC
(MFR)
Ventilation:USE WITH ADEQUATE VENTILATION
Protective Gloves:RECOMMENDED
Eye Protection:COVERALL GOGGLES
Supplemental Safety and Health
PRODUCT IS OUT OF PRODUCTION.

Chemical Properties

HCC:F4
Boiling Pt:B.P. Text:200-630F
Vapor Pres:35
Vapor Density:0.6
Spec Gravity:0.96
Evaporation Rate & Reference:1 (ETHER=1)
Solubility in Water:APPRECIABLE
Appearance and Odor:CLEAR SLIGHTLY YELLOW LIQUID, MILD KEROSENE ODOR.
Percent Volatiles by Volume:47

Stability

Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:THERMAL DECOMP MAY YIELD CO, ALDEHYDES
& PEROXIDES

Disposal

Waste Disposal Methods:MFR RECOMMENDS INCINERATION. DISPOSAL METHOD
MUST BE IAW FEDERAL, STATE & LOCAL CODES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.